Hydraulic Pressure Test
- Connect pressure gauge to main pressure test point on case (adjacent to servo cover). Transmission must be at normal operating temperature.
- Verify that pressures obtained during each phase of test are correct. See Figure . If pressures are incorrect, check for oil leaks, defective oil pump, or sticking valves in valve body assembly. See Figure .