Diagnostic Aids
WARNING: This page is about a different variant/trim than selected.
- To help locate intermittent leaks, use the J 41413-200 (J 41413-100) Evaporative Emissions System Tester (EEST) to introduce smoke into the EVAP system. See Special Tools . Move all EVAP components while observing smoke with a J 41413-SPT .
- To improve the visibility of the smoke exiting the EVAP system, observe the suspected leak area from different angles with a J 41413-SPT .
- A condition may exist where a leak in the EVAP system only exists under a vacuum condition. By using the scan tool Purge/Seal function to create a vacuum, seal the system and observe the FTP parameter for vacuum decay, this type of leak may be detected.
- If a small leak is difficult to find, it may be necessary to remove the EVAP components and test them one at a time, using the adapters in the J 41413-300 .
- The turbocharged engine is equipped with a one-way flow check valve that will prevent boost pressure from entering the purge line and the EVAP system. This check valve will also prevent flow from the J 41413-200 (J 41413-100) from the purge valve into the EVAP system. See Special Tools .