Installation Procedure
WARNING: This page is about a different variant/trim than selected.
- Lubricate the solenoid valve O-ring seals with clean engine oil.
- Install the intake (2) CMP actuator solenoid valve and bolt, as required, and tighten to 10 N.m (89 lb in).
- Install the exhaust (1) CMP actuator solenoid valve and bolt, as required, and tighten to 10 N.m (89 lb in).
- Connect the engine wiring harness electrical connector to the intake (1) or exhaust (2) camshaft position actuator solenoid valve, as required.
- Install the air cleaner assembly. Refer to Air Cleaner Assembly Replacement .
CAUTION:
Refer to Fastener Caution
.