Component Testing
WARNING: This page is about a different variant/trim than selected.
- Ignition OFF, disconnect the harness connector at the CKP sensor.
- Test for 1,850-2,450 ohms at 20°C (68°F) between the signal terminal 1 and low reference terminal 2:
- If not within the specified range, replace the CKP sensor.
IMPORTANT:
If the CKP sensor lead is damaged in any way, replace the CKP sensor.