Typical Scan Tool Data
WARNING: This page is about a different variant/trim than selected.
TP Sensor 1
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
The engine coolant temperature is greater than 70°C (158°F) and the ignition is ON with the engine is OFF. Parameter Normal Range: TP Sensor 7-21%/0.7-0.9 volts |
|||
| 5-Volt Reference | 2%/0.1 Volts | 2%/0.1 Volts | - |
| TP Sensor 1 Signal | 2%/0.1 Volts | 99%/5.0 Volts | 99%/5.0 Volts |
| Low Reference | - | 99%/5.0 Volts | - |
TP Sensor 2
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
The engine coolant temperature is greater than 70°C (158°F) and the ignition is ON with the engine is OFF. Parameter Normal Range: TP Sensor 2 45-55%/2.3-2.4 volts |
|||
| 5-Volt Reference | 2%/0.1 Vvolts | 2%/0.1 Vvolts | - |
| TP Sensor 2 Signal | 2%/0.1 Vvolts | 99%/5.0 Volts | 99%/5.0 Volts |
| Low Reference | - | 99%/5.0 Volts | - |