Component Testing
WARNING: This page is about a different variant/trim than selected.
- Ignition OFF, disconnect the harness connector at the EVAP vent solenoid.
- Test for 25-30 ohms at 20°C (68°F) between the control terminal 1 and the ignition 1 voltage terminal 2.
- If not within the specified range, replace the EVAP purge solenoid.
- Test for infinite resistance between each terminal and the EVAP purge solenoid housing.
- If not the specified value, replace the EVAP purge solenoid.
- Test the EVAP vent solenoid for correct operation. Refer to Evaporative Emission Control System Diagnosis .