Typical Scan Tool Data
WARNING: This page is about a different variant/trim than selected.
APP Sensor 1
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
The ignition is ON and the engine is OFF. Parameter Normal Range: APP Sensor 1 0.75-0.80/13-17% volt |
|||
| 5-Volt Reference | *0 volts/0% | 0 volts/0% | - |
| APP Sensor 1 Signal | 0 volts/0% | 0 volts/0% | 5.0 volts/99% |
| Low Reference | - | 5.0 volts/99% | - |
| *The vehicle may not communicate with the scan tool when the 5-Volt reference circuit is shorted to ground | |||
APP Sensor 2
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
The ignition is ON and the engine is OFF. Parameter Normal Range: APP Sensor 2 1.60-1.65 volts/28-34% |
|||
| 5-Volt Reference | *0 volts/0% | 0 volts/0% | - |
| APP Sensor 2 Signal | 0 volts/0% | 0 volts/0% | 5.0 volts/99% |
| Low Reference | - | 5.0 volts/99% | - |
| *The vehicle may not communicate with the scan tool when the 5-Volt reference circuit is shorted to ground | |||