Conditions for Setting DTC
P2120
The ECM detects that the APP sensor 1 voltage is less than 0.33 V or greater than 4.5 V for greater than 1 s.
P2122
The ECM detects that the APP sensor 1 voltage is less than 0.33 V for greater than 1 s.
P2123
The ECM detects that the APP sensor 1 voltage is greater than 4.5 V for greater than 1 s.
P2125
The ECM detects that the APP sensor 2 voltage is less than 0.33 V or greater than 4.5 V for greater than 1 s.
P2127
The ECM detects that the APP sensor 2 voltage is less than or equal to 0.33 V for greater than 1 s.
P2128
The ECM detects that the APP sensor 2 voltage is greater than 4.5 V for greater than 1 s.
P2138
The voltage difference between APP sensor 1 and APP sensor 2 exceeds a value of 5 percent with the pedal in the released position, or 10 percent with the pedal at wide open throttle (WOT) for greater than 1 s.