LEMON Manuals: Even more car manuals for everyone
Home >> Pontiac >> 2009 >> Vibe Base, 2.4 0, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 14 (HVAC System - Automatic) >> Repair Instructions >> Recirculation Actuator Replacement

Recirculation Actuator Replacement

WARNING: This page is about a different car, the 2009 Cadillac DTS. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Removing/Installing Recirculation Actuator
GM1659222Courtesy of GENERAL MOTORS CORP.
Callout Component Name

Preliminary Procedure

  1. Remove the HVAC module. Refer to HVAC Module Assembly Replacement .
  2. Disconnect the recirculation actuator electrical connector.
1 Recirculation Actuator Screw (Qty: 3)
CAUTION: Refer to Fastener Caution .

Tighten:  1.0 N.m (9 lb in)

2 Recirculation Actuator