LEMON Manuals: Even more car manuals for everyone
Home >> Pontiac >> 2009 >> Vibe Base, 2.4 0, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 14 (HVAC System - Automatic) >> Diagnostic Information and Procedures >> Air Temperature Malfunction >> Circuit/System Verification

Circuit/System Verification

WARNING: This page is about a different car, the 2009 Cadillac DTS. However, it is still accessible from the selected car via links, so may be relevant.
  1. Ignition ON, cover the sunload sensor assembly with a shop towel or other suitable item. Verify the scan tool Right Sunload Sensor and Left Sunload Sensor parameters are within 3 counts of each other.
    • If not within the specified range, refer to Sunload Sensor Circuit Malfunction.
  2. Measure actual outside air temperature using a thermometer. Compare this value to the scan tool Outside Air Temp. Raw parameter. The measured temperature should be within 5 degrees of parameter.
    • If not within the specified range, refer to Circuit/System Testing  for Evaporator and Ambient Air Temperature Sensor Circuit Malfunction.
  3. Measure actual inside air temperature using a thermometer. Compare this value to the scan tool Inside Air Temp. parameter. The measured temperature should be within 5 degrees of parameter.
    • If not within the specified range, refer to Circuit/System Testing  for Inside Air Temperature Sensor Circuit Malfunction.
  4. Measure actual evaporator air temperature using a thermometer. Compare this value to the scan tool A/C Evap. Temperature Sensor parameter. The measured temperature should be within 5 degrees of the parameter.
    • If not within the specified range, refer to Circuit/System Testing  for Evaporator and Ambient Air Temperature Sensor Circuit Malfunction.