Evaporator Temperature Sensor
The HVAC control module monitors the temperature of the air passing through the evaporator by the A/C evaporator air temperature sensor. This sensor is located on the backside of the evaporator core. The temperature is used to cycle the A/C compressor ON and OFF to prevent the evaporator core from freezing. A thermistor inside the sensor varies its resistance to monitor the evaporator air temperature. The HVAC control module monitors the voltage drop across the thermistor when supplied with a 5-volt reference signal. The HVAC control module will send a GMLAN message to the engine control module (ECM) to stop requesting the A/C compressor clutch operation if the temperature drops below -4°C (25°F). The sensor must be above 2°C (36°F) to request the A/C compressor clutch again.
The sensor operates within a temperature range between -40 to +215°C (-40 to +355°F). If the HVAC control module detects an open in the evaporator temperature sensor or circuit, the GMLAN message sent to the ECM will not submit the A/C ON request. The HVAC control module will then send a request to instrument panel for display of the SERVICE A/C SYSTEM that will be displayed on the DIC. The HVAC control module will also turn off the A/C LED on the HVAC control module as long as the condition is present, if the A/C button is pushed the LED will flash 3 times and remain OFF.