Home >> Pontiac >> 2009 >> Vibe Base, 2.4 0, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 106 (HVAC System - Automatic) >> Diagnostic Information and Procedures >> DTC B0248, B0268, B0408, B0413, B0418, B0423, B0428, B0433, B3531, B3761, B3773, or B3782 >> Diagnostic Fault Information

Diagnostic Fault Information

WARNING: This page is about a different car, the 2011 Cadillac DTS. However, it is still accessible from the selected car via links, so may be relevant.
Circuit Short to Ground Open/High Resistance Short to Voltage Signal Performance
Recirculation 5-Volt Reference B0248 61, B0408 61, B0418 61, B0268 61, B3531 61, B0428 61 B3773 06 B0268 61, B3773 06 -
Recirculation Door Position Signal B0268 61 B3773 06 B0268 61, B3773 06 -
Recirculation Door Control A B0268 61 B0268 61 B0268 61 -
Recirculation Door Control B B0268 61 B0268 61 B0268 61 -
Recirculation Low Reference - B0268 61 - -
Driver Air Temperature 5-Volt Reference B0248 61, B0408 61, B0418 61, B0268 61, B3531 61, B0428 61 B0413 06 B0408 61, B0413 06 -
Driver Air Temperature Door Position Signal B0408 61 B0413 06 B0408 61, B0413 06 -
Driver Air Temperature Door Control A B0408 61 B0408 61 B0408 61 -
Driver Air Temperature Door Control B B0408 61 B0408 61 B0408 61 -
Driver Air Temperature Low Reference - B0408 61 - -
Passenger Air Temperature 5-Volt Reference B0248 61, B0408 61, B0418 61, B0268 61, B3531 61, B0428 61 B0418 61 B0268 61, B0423 06 -
Passenger Air Temperature Door Position Signal B0418 61 B0268 61, B0423 06 B0418 61 -
Passenger Air Temperature Door Control A B0418 61 B0418 61 B0418 61 -
Passenger Air Temperature Door Control B Circuit B0418 61 B0418 61 B0418 61 -
Passenger Air Temperature Low Reference - B0418 61 - -
Mode 5-Volt Reference B0248 61, B0408 61, B0418 61, B0268 61, B3531 61, B0428 61 B0248 61 B0248 61, B3761 06 -
Mode Door Position Signal B0248 61 B0248 61, B3761 06 B0248 61, B3761 06 -
Mode Door Control A B0248 61 B0248 61 B0248 61 -
Mode Door Control B B0248 61 B0248 61 B0248 61 -
Mode Low Reference - B0248 61 - -
Auxiliary Air Temperature 5-Volt Reference B0248 61, B0408 61, B0418 61, B0268 61, B3531 61, B0428 61 B0428 61 B0428 61, B0433 06 -
Auxiliary Air Temperature Door Position Signal B0428 61 B0428 61, B0433 06 B0428 61, B0433 06 -
Auxiliary Air Temperature Door Control A B0428 61 B0428 61 B0428 61 -
Auxiliary Air Temperature Door Control B B0428 61 B0428 61 B0428 61 -
Auxiliary Air Temperature Low Reference - B0428 61 - -
Auxiliary Mode 5-Volt Reference B0248 61, B0408 61, B0418 61, B0268 61, B3531 61, B0428 61 B3531 61 B3531 61, B3782 61 -
Auxiliary Mode Door Position Signal B3531 61 B3531 61, B3782 61 B3531 61, B3782 61 -
Auxiliary Mode Door Control A B3531 61 B3531 61 B3531 61 -
Auxiliary Mode Door Control B B3531 61 B3531 61 B3531 61 -
Auxiliary Mode Low Reference - B3531 61 - -