Air Speed
The blower motor forces air to circulate within the vehicles interior. The vehicle operator determines the blower motors speed by placing the blower knob dial in a desired speed position or by selecting automatic operation. In manual operation, the blower has six speed selections. The HVAC control module may alter the blower motor speed due to compensating factors. In automatic operation, the HVAC control module will determine what blower speed is necessary in order to achieve or maintain a desired temperature. In manual and automatic operation, the blower speed temporarily reduces speed during transition between outlet modes.
Blower Motor Relay
The blower motor relay provides a supply voltage to the blower motor and blower motor control processor. The HVAC control module commands the blower motor relay ON anytime the commanded blower speed is not OFF.
Blower Motor Control Processor
The blower motor control processor is an interface between the HVAC control module and the blower motor. The blower motor speed control, blower motor supply voltage and ground circuits enable the control processor to operate. The HVAC control module provides a pulse width modulation (PWM) signal to the control processor in order to command the blower motor speed. The control processor uses the blower motor ground as a low side control to adjust the blower motor speed.
Afterblow
Afterblow is a feature that dries the evaporator core by operating the blower motor after the engine is turned OFF. This reduces the amount of microbial growth that can create undesirable odors. The vehicle does not come equipped with the afterblow feature turned ON. If the afterblow feature is required due to an odor concern, it must be turned ON by reprogramming the HVAC control module. Refer to Service Programming System (SPS) .
After the HVAC control module has been programmed for afterblow, the following conditions must be met for afterblow to operate:
- The engine has been turned OFF for at least 30 minutes.
- The ambient air temperature is at least 22°C (70°F).
- The A/C compressor operated for more than 2 minutes before shut down.
- The system voltage is at least 12 volts.
Once the above conditions have been met, the following sequence of events will occur:
- The blower motor will RUN for 20 seconds.
- The blower motor will be OFF for 10 minutes.
- The blower will repeat step 1 and 2 above for 2 more cycles.
OnStar® Blower Control ON/OFF
During OnStar® audio control ON, the HVAC control module receives signals from OnStar® to reduce blower speed level. When OnStar® audio control is active, the blower control runs the fan at a reduced speed to enable audio communications. This ensures that all incoming and outgoing voice calls will be recognized by the OnStar® module. The driver is allowed to override the OnStar® auto blower level by increasing or decreasing it manually to any desired level. When OnStar® no longer sends the request for blower control the HVAC control module will cancel OnStar® blower control and resume previous blower level if no manual override of the blower was selected.