Home >> Pontiac >> 2009 >> G3 Automatic >> Repair and Diagnosis >> Transmission >> Hydraulic Diagrams >> Automatic Transmission - AISIN 81-40LE - Removal & Installation, Service, Overhaul, Troubleshooting & Diagnosis >> Repair Instructions - On Vehicle >> Floor Shift Control Cable Replacement >> Installation Procedure

Installation Procedure

    Fig 1: Shift Control Cable, Bracket & Fastener
    GM1245826Courtesy of GENERAL MOTORS CORP.
  1. Install the shift control cable to the vehicle.
  2. Connect the shift control cable to the shift control cable fastener.
  3. Install the E-ring to the shift control cable bracket and connect the shift control cable.
  4. Fig 2: Shift Control Cable & PNP Switch Lever
    GM1245820Courtesy of GENERAL MOTORS CORP.
  5. Connect the shift control cable to the PNP switch.
  6. Install the shift control cable retaining E-ring.
  7. Fig 3: Shift Control Cable & Control Cable Adjusting Nut
    GM1245815Courtesy of GENERAL MOTORS CORP.
  8. Connect the shift control cable to the shift control lever assembly.
  9. CAUTION: Refer to Fastener Caution .
  10. Install the cable adjusting nut.

    Tighten:  Tighten the cable adjusting nut to 8 N.m (71 lb in).

  11. Install the trim panel to the floor console. Refer to Front Floor Console Replacement (Notchback) or Front Floor Console Replacement (Hatchback) .
  12. Connect the negative battery cable.