LEMON Manuals: Even more car manuals for everyone
Home >> Pontiac >> 2008 >> Vibe Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 88 (Automatic Transmission - 6L50/6L80/6L90 - Removal & Installation, Service, Overhaul, Troubleshooting & Diagnosis) >> Off-Vehicle Repair Instructions >> Torque Converter Housing with Fluid Pump Installation

Torque Converter Housing with Fluid Pump Installation

WARNING: This page is about a different car, the 2008 Hummer H2. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Torque Converter Housing with Fluid Pump Installation
GM1696437Courtesy of GENERAL MOTORS CORP.
Callout Component Name
1 NEW Fluid Pump Seal
2 Torque Converter (with Fluid Pump) Housing Assembly
NOTE: Ensure the turbine shaft (O-ring) seal is not installed prior to installing the torque converter housing assembly. The seal may become cut or damaged during installation of the torque converter housing assembly.
3 Bolts M10 x 50 (Qty: 9)
NOTE: Refer to Fastener Notice .

Procedure: 
Tighten in the sequence shown.

Tighten:  72 N.m (53 lb ft)

4 NEW Turbine Shaft (O-Ring) Seal