Removal Procedure
WARNING: This page is about a different variant/trim than selected.
- Remove the air cleaner inlet duct. Refer to Air Cleaner Inlet Duct Replacement .
- Disconnect the engine wiring harness electrical connector from the camshaft position (CMP) sensor.
- Remove the CMP sensor bolt (2).
- Remove the CMP sensor (1).
- Inspect the CMP sensor O-rings for wear, cracks, or leakage if the sensor is being reused. Replace the O-rings if damaged.