Illuminated Entry Lamps Malfunction - with UUC
WARNING: This page is about a different car, the 2009 Pontiac Torrent and 2009 Chevrolet Equinox. However, it is still accessible from the selected car via links, so may be relevant.
- Ignition OFF, disconnect the X3 and X4 harness connectors at the BCM.
- Ignition ON, verify that a test lamp illuminates between the B+ circuit terminals listed below and ground:
- Terminal 2 X3
- Terminal 2 X4
- If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
- Ignition OFF, connect the X3 and X4 harness connectors at the BCM.
- Disconnect the harness connector at the dome lamp switch.
- Connect a test lamp between the control circuit terminal A and ground.
- Command the Courtesy Lamp ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
- If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM.
- If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM.
- Ignition OFF, connect the harness connector at the dome lamp switch.
- Disconnect the harness connector at the inoperative courtesy/reading lamp assembly.
- Ignition OFF, scan tool OFF, doors CLOSED, interior lamps OFF, test for less than 5.0 ohms between the appropriate ground circuit terminal listed below and ground.
- Dome lamp terminal B
- Overhead console Courtesy/reading lamps terminal B
- Cargo lamp terminal D
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Connect a test lamp between the appropriate control circuit terminal listed below and ground:
- Dome lamp terminal C
- Cargo lamp terminal B
- Dome lamp switch in DOOR position, command the Courtesy Lamp ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
- If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the dome lamp switch.
- If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the dome lamp switch.
- If all circuits test normal, replace the inoperative courtesy/reading lamp assembly.