Circuit/System Testing
WARNING: This page is about a different car, the 2009 Pontiac Torrent and 2009 Chevrolet Equinox. However, it is still accessible from the selected car via links, so may be relevant.
P0451 and P0454
- Start the engine with the J 41413-200 connected to the fuel filler neck.
- Allow the engine to idle.
- Use the Purge/Seal function to seal the system with a scan tool.
- Command the EVAP canister purge solenoid valve to 30 percent.
- Observe the vacuum/pressure gage on the J 41413-200 and the FTP parameter on the scan tool.
- Allow the vacuum to increase on the gage of the J 41413-200 until it reaches approximately 16 inches H2O, or until the vacuum reached the abort limit on the scan tool.
- Use the Purge/Seal function to seal the system with a scan tool.
- If the difference between the FTP parameter on a scan tool and the vacuum/pressure gage on the J 41413-200 is more than 1 inch H2O, replace the FTP sensor.
- If the Fuel Tank Pressure Sensor parameter on a scan tool display is less than 3.2 volts, replace the FTP sensor.
IMPORTANT:
Refer to the J 41413-200
operation manual for detailed instructions.
P0452 and P0453
- Ignition OFF, disconnect the harness connector at the FTP sensor.
- Ignition OFF, ensure that the ECM completely powers down and test for less than 5 ohms between the low reference circuit terminal 2 and ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the control module.
- Ignition ON, test for 4.8-5.2 volts between the 5-volt reference circuit terminal 3 and ground.
- If less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the control module.
- If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the control module.
- Verify the scan tool FTP sensor parameter is less than 0.2 volt.
- If greater than the specified range, test the signal circuit terminal 1 for a short to voltage. If the circuit tests normal, replace the control module.
- Install a 3A fused jumper wire at the signal circuit terminal 1 and the 5-volt reference circuit terminal 3. Verify the scan tool FTP sensor voltage parameter is greater than 4.7 volts.
- If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the control module.
- If all circuits test normal, replace the FTP sensor.