Conditions for Running the DTC
WARNING: This page is about a different car, the 2009 Pontiac Torrent and 2009 Chevrolet Equinox. However, it is still accessible from the selected car via links, so may be relevant.
P0450
- DTC P0100, P0101, P0102, P0103, P0116, P0117, P0118, P0119, P0443, P0449, P0458, P0459, P0498, P0499, P050A, P0506, P0507, P0700, P2227, P2228, or P2229 is not set.
- The engine is operating.
- The ambient air temperature is greater than -7°C (+19°F).
- The vehicle speed is less than 31 km/h (19 mph).
- The ECM has commanded the EVAP canister vent valve open for greater than 3 seconds, 4 seconds for LLT.
- DTC P0450 runs continuously once the above conditions are met for approximately 25 seconds.
P0451 Condition 1
- DTC P0100, P0101, P0102, P0103, P0116, P0117, P0118, P0119, P0443, P0449, P0458, P0459, P0498, P0499, P050A, P0506, P0507, P0700, P2227, P2228, or P2229 is not set.
- The engine is operating for greater than 1 second.
- The engine is idling.
- The ambient air temperature is greater than -7°C (+19°F).
- The vehicle speed is less than 10 km/h (6 mph) for greater than 29 seconds.
- The BARO is greater than 68 kPa.
- The fuel level is between 11-88 percent.
- The ECM has commanded the EVAP canister purge solenoid ON.
- The ECM has commanded the EVAP canister vent valve closed for greater than 4 seconds.
- DTC P0451 runs continuously when the above conditions are met for approximately 26 seconds.
P0451 Condition 2
- DTC P0100, P0101, P0102, P0103, P0116, P0117, P0118, P0119, P0443, P0449, P0458, P0459, P0498, P0499, P050A, P0506, P0507, P0700, P2227, P2228, or P2229 is not set.
- The engine is operating.
- The BARO is greater than 68 kPa.
- The fuel level is between 11-88 percent.
- The ECM has commanded the EVAP canister purge solenoid OFF.
- The ECM has commanded the EVAP canister vent valve open.
OR
- The fuel level is less than 60 percent, 73 percent for LLT.
- The vehicle speed is between 10-76 km/h (6-47 mph) fro greater than 30 seconds.
- The ECM has commanded the EVAP canister purge solenoid ON.
OR
- The calculated ambient air temperature is between 4-35°C (39-95°F) for greater than 3 seconds.
- DTC P0451 runs continuously when the above conditions are met for approximately 7 seconds.