LEMON Manuals: Even more car manuals for everyone
Home >> Pontiac >> 2008 >> Torrent GXP, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 130 (HVAC System - Manual) >> Diagnostic Information and Procedures >> Air Temperature Malfunction >> Circuit/System Verification >> Notes

Circuit/System Verification: Notes

WARNING: This page is about a different car, the 2009 Pontiac Torrent and 2009 Chevrolet Equinox. However, it is still accessible from the selected car via links, so may be relevant.
  1. Measure actual outside air temperature using a thermometer. Compare this value to the scan tool Outside Air Temp. Raw parameter. The measured temperature should be within 5 degrees of parameter.
  2. Measure actual inside air temperature using a thermometer. Compare this value to the scan tool Inside Air Temp. parameter. The measured temperature should be within 5 degrees of parameter.
  3. Measure actual temperature using a thermometer at the A/C EVAP. temperature sensor. Compare this value to the scan tool A/C EVAP. Temperature Sensor parameter. The measured temperature should be within 5 degrees of the parameter.