Removal Procedure
- Remove the case side cover. Refer to Control Valve Body Cover Replacement .
- Remove the oil pump bolts (230, 231).
- Remove the oil pump (200) from the valve body (300).
- Clean and inspect the oil pump. Refer to Fluid Pump Components Disassemble and Fluid Pump Components Assemble .
NOTE:
Do NOT remove the three bolts which hold the pump together.