Exhaust Gas Recirculation Valve and Pipe Installation
WARNING: This page is about a different variant/trim than selected.
- Install the EGR inlet pipe into the RH exhaust manifold as the EGR valve adapter assembly is installed onto the cylinder head.
- Install the EGR valve adapter assembly to cylinder head bolts and the EGR inlet pipe to RH exhaust manifold bolt.
Tighten:
- Tighten the EGR valve adapter assembly to cylinder head bolts to 50 N.m (37 lb ft).
- Tighten the EGR inlet pipe to RH exhaust manifold bolt to 29 N.m (21 lb ft).
- Install the EGR valve outlet pipe to the lower intake and the EGR valve adapter assembly.
- Install the EGR valve outlet pipe bolt and nut.
Tighten: Tighten the EGR valve outlet pipe bolt and nut to 29 N.m (21 lb ft).
- Install the EGR valve gasket and EGR valve.
- Install the EGR valve nuts.
Tighten: Tighten the EGR valve nuts to 29 N.m (21 lb ft).
- Install the exhaust manifold heat shield.
- Install the exhaust manifold heat shield bolts.
Tighten: Tighten the exhaust manifold heat shield bolts to 10 N.m (89 lb in).
- Install the heated oxygen sensor.
Tighten: Tighten the heated oxygen sensor to 42 N.m (31 lb ft).
IMPORTANT:
Inspect the exhaust gas recirculation (EGR) inlet/outlet pipes for leaks before installation. If cracks, deformations or any visible signs of leaking are present, replace the appropriate part.
NOTE:
Refer to FASTENER NOTICE
.