LEMON Manuals: Even more car manuals for everyone
Home >> Pontiac >> 2007 >> Vibe Standard >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Instrument Panel System Displays And Gauges >> Diagnostic Information and Procedures >> Gages Inoperative - All

Gages Inoperative - All

Gages Inoperative - All

Step Action Yes No
Schematic Reference: Instrument Cluster Schematics 
1 Did you review the Instrument Panel, Gages and Console Description and Operation and perform the necessary inspections? Go to Step 2  Go to Symptoms - Instrument Panel, Gages and Console 
2 Verify that the instrument cluster gages are inoperative.
Does the system operate normally?
Go to Testing for Intermittent Conditions and Poor Connections Go to Step 3 
3
  1. Disconnect the instrument cluster connector.
  2. Test for an open condition between terminal 40 and a good ground. Refer to Circuit Testing .
Does an open condition exist?
Go to Step 4  Go to Step 5 
4 Repair the open in the WH/BK wire between the instrument cluster and G200. Refer to Wiring Repairs .
Did you complete the repair?
Go to Step 8  -
5 With connector still disconnected.
Test terminal 1 for open or short to ground. Refer to Circuit Testing .
Is open or short present?
Go to Step 6  Go to Step 7 
6 Repair open or short to ground. Refer to Wiring Repairs .
Did you repair short or open?
Go to Step 8  -
7 Replace the instrument cluster. Refer to Instrument Cluster Replacement .
Did you complete the replacement?
Go to Step 8  -
8 Operate the system in order to verify the repair.
Did you correct the condition?
System OK Go to Step 3