Circuit/System Testing
- Ignition OFF, disconnect the DIC switch connector.
- Test for less than 1 ohm of resistance between the DIC switch ground circuit and ground.
- If greater than 1 ohm, test the ground circuit for an open/high resistance.
- Ignition ON, verify the scan tool Trip Reset Switch parameter is Inactive.
- If not inactive, test the signal circuit for a short to ground. If the circuit tests normal, replace the IPC.
- Install a 3-amp fused jumper wire between the signal circuit and ground. Verify the scan tool Trip Reset Switch parameter is Active.
- If not active, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the IPC.
- If all circuits test normal, test or replace the DIC switch.