Conditions for Setting the DTC
WARNING: This page is about a different variant/trim than selected.
P2430
- The measured AIR pressure change does not meet expected pressure changes during AIR pump phase 1 or phase 2 operation.
- DTC P2430 sets within 8 seconds when the above condition is met.
P2431
- The PCM determines that the difference between the AIR pressure sensor and the barometric pressure (BARO) sensor signals is greater than 10 kPa when the AIR pump is commanded OFF.
OR
- The PCM determines that the difference between the AIR pressure sensor and the BARO sensor signals is greater than 50 kPa when the AIR pump is commanded ON.
- P2432
-
The pressure sensor signal is less than 0.2 volt for at least 12.5 seconds.
- P2433
-
The pressure sensor signal is more than 4.8 volts for at least 12.5 seconds.