Conditions for Running
WARNING: This page is about a different variant/trim than selected.
Scan Tool Service Bay Test equipped vehicle
- The intake air temperature (IAT) is more than 5°C (40°F).
- The engine coolant temperature (ECT) is more than 5°C (40°F).
- The fuel level is between 25-90 percent.
- The battery voltage is between 10.5-18 volts.
Non Scan Tool Service Bay Test equipped vehicles
- The BARO pressure indicates that the altitude is less than 2,400 meters (8,000 feet).
- The IAT is between 5-35°C (40-95°F) at engine start.
- The ECT is between 5-35°C (40-95°F) at engine start.
- The fuel level is between 25-90 percent.
- The battery voltage is between 10.5-18 volts.
- The vehicle is driven for at least 15 minutes.