Removal Procedure
WARNING: This page is about a different variant/trim than selected.
- Disconnect the electrical connector (1) from the evaporative emission (EVAP) canister purge valve (2).
- Disconnect the 2 vacuum hoses (4) from the EVAP canister purge valve (2).
- Remove the EVAP canister purge valve from the air inlet duct hose.
- Inspect the EVAP canister purge valve, and the EVAP purge system for carbon particle contamination, before replacing the EVAP canister purge valve.