System Description
The DTC P2445 Secondary Air Injection (AIR) System Pump Stuck Off diagnostic monitors the AIR pump activity. The AIR system helps reduce exhaust emissions. The system forces fresh filtered air into the exhaust stream in order to accelerate the catalyst operation. An electric air pump, the AIR pump, provides filtered air on demand to the AIR shut-off valve. The AIR shut-off valve controls the flow of air from the AIR pump to the exhaust manifold. The AIR solenoid valve supplies the manifold vacuum that is used to operate the AIR shut-off valve. A pressure sensor is used to monitor the air flow from the AIR pump. By comparing the measured pressure against the expected pressure the pressure sensor can detect faults in the AIR pump, AIR shut-off valve, and the AIR solenoid valve. The pressure sensor can also detect leaks in the AIR system plumbing.