Removal Procedure
WARNING: This page is about a different variant/trim than selected.
- Disconnect the electrical connector (1) from the EVAP canister purge valve (2).
- Remove the purge hose (3) from the EVAP canister purge valve (2).
- Remove the vacuum hose (4) from the EVAP canister purge valve (2).
- Remove the EVAP canister purge valve from the air cleaner housing.
- Inspect the EVAP canister purge valve and the EVAP purge system for carbon particle contamination before replacing the EVAP canister purge valve.