Secondary Air Injection (AIR) Shut-Off Valve Replacement Bank 2
REMOVAL PROCEDURECAUTION: Allow the engine to cool before servicing the secondary air injection AIR system In order to reduce the chance Of severe burns.
1. Turn OFF the ignition.
2. Remove the ignition control module and coils.
3. Disconnect the Secondary Air Injection (AIR) crossover pipe from the shut-off valve.
4. Disconnect the vacuum line from the shut-off valve.
5. Remove the AIR shut-off valve nut.
6. Remove the shut-off valve bolts from the manifold pipe.
7. Remove the shut-off valve.
INSTALLATION PROCEDURE
NOTE: Refer to Fastener Notice in Service Precautions.
1. Install the shut-off valve to the manifold pipe.
Tighten
Tighten the AIR shut-off valve to 20 N.m (15 lb ft)
2. Install the AIR shut-off valve nut.
Tighten
Tighten the nut to 10 N.m (89 lb in).
3. Connect the vacuum line to the shut-off valve.
4. Connect the AIR crossover pipe to the shut-off valve.
5. Install the ignition control module.