Scan Tool Does Not Power Up
- Check CIG/ACCY fuse in instrument panel fuse block. If fuse is okay, go to next step. If fuse is blown, check for short to ground in Orange wire between terminal No. 16 at Data Link Connector (DLC) and CIG/ACCY fuse. Repair wiring as necessary and retest.
- Check for battery voltage at terminal No. 16 (Orange wire) at DLC. If battery voltage is present, go to next step. If battery voltage is not present, check for an open in Orange wire between DLC and CIG/ACCY fuse. Repair wiring as necessary.
- Check for open in Black wire between ground and terminal No. 4 at DLC. If ground circuit is okay, go to next step. If faulty circuit is found, repair Black wire as necessary.