DTC 25 - Initiator Circuit Short To Ignition: Description
During INITIATOR ASSEMBLY RESISTANCE test, DERM grounds DRIVER-SIDE LOW terminal B8 for 50 milliseconds and measures voltage at DRIVER-SIDE LOW and PASSENGER-SIDE LOW. DERM then grounds PASSENGER-SIDE LOW terminal B7 for 50 milliseconds, and again measures voltage at DRIVER-SIDE LOW and PASSENGER-SIDE LOW.