Only One Horn Inoperative
Disconnect electrical connector from inoperative horn. Connect a test light to horn connector terminal "B" (Dark Green wire) and ground. Push horn button. If test light is off, check for open in Dark Green wire between horn relay and horn. If test light is on, check for poor connection at horn. If connection is okay, replace horn.
HORN RELAY LOCATION
| Application | Location |
|---|---|
| "F" Body | Behind Instrument Panel, In Convenience Center |