LEMON Manuals: Even more car manuals for everyone
Home >> Pontiac >> 1993 >> Bonneville SE >> Repair and Diagnosis >> Restraints >> Air Bag, SRS >> Air Bag Restraint System - SSE & SSEI >> Diagnostic Charts >> Code 43 (Chart 2) - Driver Source Feed Low >> Failure Conditions

Failure Conditions

Code 43 sets when voltage at DRIVER SENSE LOW input is 39-50 percent of DRIVER 36VLR output and DRIVER SOURCE SENSE input is less than DRIVER 36VLR output minus 6 volts for 500 milliseconds.