Code 34 - Dual Pole Arming Sensor Feed Open: Description
Upon passing test for Code 14, Code 34 sets if failure conditions were present at initial TURN-ON tests. When test for Code 14 fails, Code 34 does not set. If neither fault or clear conditions are met, state of fault during previous ignition cycle is used. Code 34 indicates an open in IGNITION 1 circuit feeding dual pole arming sensor.