Failure Conditions
Codes 21 and 22 will set if voltage at SENSE LOW input (terminal A6) is less than 5 volts during STEERING COLUMN RESISTANCE test. This occurs when FORCE HI output (terminal A4) is open and results in an undetermined steering column resistance.