LEMON Manuals: Even more car manuals for everyone
Home >> Pontiac >> 1993 >> Bonneville SE >> Repair and Diagnosis >> Restraints >> Air Bag, SRS >> Air Bag Restraint System - Except SSE & SSEI >> Diagnostic Charts >> Code 32 - Grounded 36VLR To Deployment Loop >> Description

Code 32 - Grounded 36VLR To Deployment Loop: Description

Voltage at SENSE LOW input (terminal A6) is 41-61 percent of 36-Volt Loop Reserve (36VLR) output voltage when 36VLR of Diagnostic Energy Reserve Module (DERM) is charged. Should circuit short to ground between 36VLR and arming sensor, IGNITION 1 voltage will supply deployment loop. Voltage at SENSE LOW input (terminal A6) will decrease due to decrease in supply voltage, and Code 32 will set after 700 milliseconds. Code 32 indicates a short to ground in wiring between 36VLR of DERM and arming sensor.