Code 25 (Chart 1) - Short To Battery In Steering Column: Description
DERM grounds FORCE LOW output (terminal A10) and then monitors voltage at SENSE LOW input (terminal A6). Code 25 is an indication of a short to system voltage in steering column, dual sensor or associated wiring. In addition, this code can be set when actual resistance of 100-ohm resistor within resistor module is too high or is open.