Fluid Level Does Not Cycle Between Full & Empty
There could be air in fluid. To remove air, cycle pump 10-15 times. If accumulator precharge pressure is low, replace accumulator.
There could be air in fluid. To remove air, cycle pump 10-15 times. If accumulator precharge pressure is low, replace accumulator.