Engine - Stalling on Park-to-Drive/Reverse Manuever
87PONTIAC12Number 86-6(Gasoline)-81 Date 10/87
Subject: ENGINE STALLING ON PARK-TO-DRIVE/REVERSE
1986 2.5L FIERO WITH AUTOMATIC TRANSAXLE
Customer comments of stalling on 2.5L engine during a park-to-drive/ reverse maneuver following a hot soak may be received. If normal diagnostic and service procedures as shown in Section 6E2 of the service manual do not correct this condition, a new PROM package, P/N 16085998, should be installed.
This applies only to 2.5L Fiero models with automatic transaxle.
Use applicable labor operation and time in accordance with the Labor Time Guide.