Emissions Maintenance Reminder Reset Procedure
NOTE:
If any other scan tool is used, use scan tool manufacturer's instructions.
- Attach DRB-II tester to diagnostic connector.
- Turn ignition on but do not start engine.
- Access SELECT SYSTEMS function of DRB-II tester.
- Select appropriate engine.
- Select with or without A/C.
- Select FUEL & IGNITION.
- Select ADJUSTMENTS.
- Select RESET EMR LIGHT.
- Reset EMR light.
- When DRB-II is finished resetting light, DRB-II display will read EMR LIGHT IS RESET.
NOTE:
If Single Module Engine Controller (SMEC) or Single Board Engine Controller (SBEC) is replaced, vehicle mileage must be programmed back into the SMEC/SBEC. DRB-II tester MUST be used for this procedure. If the following procedure is not performed, EMR light will not turn on at the proper mileage intervals.