Instrument Panel - Standard: Testing: Ammeter
- On Conquest, and models with printed circuit board instrumentation, access to the rear of instrument is necessary. Attach ohmmeter probes to ammeter gauge terminals.
- For Ram-50, and models with shunt type ammeter, attach ohmmeter probes to White and White/Black wire terminals. See Fig 1 . Average resistance should be .173 ohms.