Pressure Tank Bleeding: Notes
PRESSURE TANK CAUTIONS: To safeguard against air entering system, observe the following:
- Do not shake or agitate pressure tank after air pressure has been introduced.
- Do not move pressure tank position, but bring air line to tank when additional air pressure is required.
- Be sure that valves on pressure tank lines are not defective and allowing air to be sucked in when fluid passes through lines.
- Keep pressure tank at least 1/3 full of fluid at all times.
- When pressure tank is full of air bubbles, release air pressure so bubbles can escape, then repressurize.