DTC Detection Logic
|
DTC No. |
CONSULT screen items (Trouble diagnosis content) |
DTC detection condition |
||
|
B1231-11 |
DTRL RH PWR SPLY CIRC (Daytime running light right hand power supply circuit) |
[CIRCUIT SHORT TO GROUND] |
Diagnosis condition |
When daytime running light ON conditions are satisfied (smart FET inside IPDM E/R is ON) |
|
Signal (terminal) |
Daytime running light RH power supply circuit |
|||
|
Threshold |
Overcurrent is detected |
|||
|
Diagnosis delay time |
1 second or less |
|||