Diagnosis Procedure
- CHECK DAYTIME RUNNING LIGHT RH POWER SUPPLY CIRCUIT (SHORT)
- Ignition switch OFF.
- Disconnect IPDM E/R connector and front combination lamp RH connector.
- Check continuity between IPDM E/R harness connector and ground.
IPDM E/R
--
Continuity
Connector
Terminal
E44
58
Ground
No
Is the inspection result normal?
YES
GO TO 2.
NO
Repair or replace harness.
- CHECK DAYTIME RUNNING LIGHT RH POWER SUPPLY
CONSULT
- Connect IPDM E/R connector.
- Ignition switch ON.
- Turn lighting switch 1ST.
- Select "DAYTIME RUNNING LIGHT" in "Active Test" mode of "IPDM E/R".
- With operating the test items, check the voltage between front combination lamp RH harness connector and ground.
+
-
Test item
Voltage
(Approx.)
Front combination lamp RH
Connector
Terminal
E38
5
Ground
DAYTIME RUNNING LIGHT
On
Battery voltage
Off
0 V
Is the inspection result normal?
YES
GO TO 3.
NO
Replace IPDM E/R. Refer to Removal and Installation .
- CHECK DAYTIME RUNNING LIGHT RH
Check the daytime running light RH. Refer to Component Inspection .
Is the inspection result normal?
YES
Inspection End.
NO
Replace front combination lamp RH. Refer to Removal and Installation .