DTC Diagnosis Procedure
WARNING: This page is about a different variant/trim than selected.
- CHECK TCM POWER SOURCE
- Turn ignition switch OFF.
- Disconnect A/T assembly connector.
- Check the voltage between A/T assembly harness connector terminal and ground.
?
?
Condition
Voltage
A/T assembly
Connector
Terminal
Ground
Always
9 - 16 V
F55
2
Is the inspection result normal?
- DETECT MALFUNCTIONING ITEM
Check the following items:
- Open circuit or short circuit in harness between battery positive terminal and A/T assembly harness connector terminal 2.
- Battery
- 10A fuse (No. 30)
Is the inspection result normal?
YES
Check intermittent incident. Refer to Intermittent Incident .
NO
Repair or replace damaged parts.