Sensor power supply 3
WARNING: This page is about a different variant/trim than selected.
- EVAP control system pressure sensor
- Fuel rail pressure sensor
- Engine oil pressure sensor
- Refrigerant pressure sensor
- Power steering pressure sensor
- CHECK APP SENSOR 2 POWER SUPPLY CIRCUIT-1
- Turn ignition switch OFF.
- Disconnect accelerator pedal position (APP) sensor 2 harness connector.
- Turn ignition switch ON.
- Check the voltage between APP sensor 2 harness connector and ground.
+
-
Voltage
(Approx.)
APP sensor 2
Connector
Terminal
E20
1
Ground
5 V
Is the inspection result normal?
YES
INSPECTION END
NO
GO TO 2.
- CHECK APP SENSOR 1 POWER SUPPLY CIRCUIT-2
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between APP sensor 2 harness connector and ECM harness connector.
+
-
Continuity
APP sensor 2
ECM
Connector
Terminal
Connector
Terminal
E20
1
E77
142
Existed
Is the inspection result normal?
YES
GO TO 3.
NO
Repair open circuit.
- CHECK SENSOR POWER SUPPLY 2 CIRCUIT
- Disconnect following sensors harness connector.
- Check harness for short to power and short to ground, between the following terminals.
ECM
Sensor
Connector
Terminal
Name
Connector
Terminal
E77
142
APP sensor 2
E20
1
F78
30
Multi-way control valve
F92
5
Fan clutch assembly
F97
2
F79
73
Camshaft position sensor (Bank 2)
F58
1
Exhaust valve timing control position sensor (Bank 2)
F72
1
Is the inspection result normal?
YES
GO TO 4.
NO
Repair short to ground or short to power in harness or connectors.
- CHECK COMPONENTS
Check the following.
- APP sensor 2 (Refer to Component Inspection (Accelerator Pedal Position Sensor) .)
- Multi-way control valve (Refer to Component Inspection (Multi-way Control Valve) .)
- Fan clutch assembly (Refer to Component Inspection (Cooling Fan Speed Sensor) .)
- Camshaft position sensor (Bank 2) (Refer to Component Inspection (Camshaft Position Sensor) .)
- Exhaust valve timing control position sensor (Bank 2) (Refer to Component Inspection (Exhaust Valve Timing Control Position Sensor) .)
Is the inspection result normal?
YES
Perform Intermittent Incident .
NO
Replace malfunctioning component.