Main Bearing Cap Sub Bolt Outer Diameter
WARNING: This page is about a different variant/trim than selected.
- Measure the outer diameters (A), (B) at two positions as shown in the figure.
(C)
: 20 mm (0.79 in)
(D)
: 15 mm (0.59 in)
(E)
: 9 mm (0.35 in)
- If reduction appears in (A) range, regard it (B).
Limit [(B) - (A)]
: 0.10 mm (0.0039 in)
- If it exceeds the limit (large difference in dimensions), replace main bearing cap sub bolts with new one.