LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2021 >> NV2500 HD S >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 13 (Engine Control System (DTC/Circuit Diagnosis) (5.6L) (3 Of 6)) >> DTC/Circuit Diagnosis >> DTC P0193: FRP Sensor >> DTC Diagnosis Procedure

DTC Diagnosis Procedure

WARNING: This page is about a different variant/trim than selected.
NOTE: Turning the ignition switch ON with FRP sensor harness connector disconnected causes ECM to detect DTC P0190. Be sure to erase the DTC when the diagnosis procedure.
  1. CHECK FRP SENSOR POWER SUPPLY-I 
    1. Turn ignition switch OFF.
    2. Disconnect FRP sensor connector.
    3. Turn ignition switch ON.
    4. Check the voltage between FRP sensor harness connector terminals.

      FRP sensor

      Voltage

      (Approx.)

      Connector

      +

      -

      terminal

      F91

      1

      3

      5 V

    Inspection result normal?

    YES

    GO TO 4.

    NO

    GO TO 2.

  2. CHECK FRP SENSOR POWER SUPPLY-II 

    Check the voltage between FRP sensor harness connector and the ground.

    +

    -

    Voltage

    (Approx.)

    FRP sensor

    Connector

    Terminal

    F91

    1

    Ground

    5 V

    Is inspection result normal?

    YES

    GO TO 3.

    NO

    Repair or replace error-detected parts.

  3. CHECK SENSOR POWER SUPPLY 3 CIRCUIT 

    Perform DTC Diagnosis Procedure .

    Is inspection result normal?

    YES

    Perform the trouble diagnosis for power supply circuit. Refer to DTC Diagnosis Procedure .

    NO

    Repair or replace error-detected parts.

  4. CHECK FRP SENSOR GROUND CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between FRP sensor harness connector and ECM harness connector.

      +

      -

      Continuity

      FRP sensor

      ECM

      Connector

      Terminal

      Connector

      Terminal

      F91

      3

      F78

      13

      Existed

    Is inspection result normal?

    YES

    GO TO 5.

    NO

    Repair or replace error-detected parts.

  5. CHECK ECM GROUND CIRCUIT 

    Check the continuity between ECM harness connector and the ground.

    ECM

    Ground

    Continuity

    Connector

    Terminal

    E77

    147

    Ground

    Existed

    149

    152

    Is inspection result normal?

    YES

    GO TO 6.

    NO

    Repair or replace error-detected parts.

  6. CHECK FRP SENSOR SIGNAL CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between FRP sensor harness connector and ECM harness connector.

      +

      -

      Continuity

      FRP sensor

      ECM

      Connector

      Terminal

      Connector

      Terminal

      F91

      2

      F78

      25

      Existed

    4. Also check harness for short to ground and to power.

    Is inspection result normal?

    YES

    GO TO 7.

    NO

    Repair or replace error-detected parts.

  7. CHECK FRP SENSOR 

    Refer to Component Inspection (Fuel Rail Pressure Sensor) .

    Is inspection result normal?

    YES

    INSPECTION END

    NO

    Repair or replace error-detected parts.