DTC Diagnosis Procedure
- CHECK FUEL RAIL PRESSURE (FRP) SENSOR POWER SUPPLY-I
- Turn ignition switch OFF.
- Disconnect FRP sensor connector.
- Turn ignition switch ON.
- Check the voltage between FRP sensor harness connector terminals.
FRP sensor
Voltage
(Approx.)
Connector
+
-
terminal
F91
3
1
5 V
Inspection result normal?
YES
GO TO 7.
NO
GO TO 2.
- CHECK FRP SENSOR POWER SUPPLY-II
Check the voltage between FRP sensor harness connector and the ground.
+
-
Voltage
(Approx.)
FRP sensor
Connector
Terminal
F91
3
Ground
5 V
Is inspection result normal?
YES
GO TO 5.
NO
GO TO 3.
- CHECK FRP SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between FRP sensor harness connector and ECM harness connector.
FRP sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
F91
3
F78
13
Existed
- Also check harness for short to power and short to ground.
Is inspection result normal?
YES
GO TO 4.
NO
Repair or replace error-detected parts.
- CHECK SENSOR POWER SUPPLY 3 CIRCUIT
Perform Diagnosis Procedure .
Is inspection result normal?
YES
Perform the trouble diagnosis for ECM power supply circuit. Refer to DTC Diagnosis Procedure .
NO
Repair or replace error-detected parts.
- CHECK FRP SENSOR GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between FRP sensor harness connector and ECM harness connector.
FRP sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
F91
1
F78
29
Existed
- Also check harness for short to power.
Is inspection result normal?
YES
GO TO 6.
NO
Repair or replace error-detected parts.
- CHECK ECM GROUND CIRCUIT
- Check the continuity between ECM harness connector and ground.
ECM
--
Continuity
Connector
Terminal
F78
10
Ground
Existed
50
55
E77
147
149
152
- Also check harness for short to power.
Is the inspection result normal?
YES
INSPECTION END
NO
Repair or replace error-detected parts.
- Check the continuity between ECM harness connector and ground.
- CHECK FRP SENSOR SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between FRP sensor harness connector and ECM harness connector.
FRP sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
F91
2
F78
25
Existed
- Also check harness for short to power and short to ground.
Is inspection result normal?
YES
GO TO 8.
NO
Repair or replace error-detected parts.
- CHECK FRP SENSOR
Check the FRP sensor. Refer to Component Inspection (Fuel Rail Pressure Sensor) .
Is inspection result normal?
YES
INSPECTION END
NO
Repair or replace error-detected parts.